Changzhou Tonghui Electronic Co., Ltd.
Products
Contact Us
  • Contact Person : Mr. Lu David
  • Company Name : Changzhou Tonghui Electronic Co., Ltd.
  • Tel : 86-519-85195566
  • Fax : 86-519-85109972
  • Address : Jiangsu,Changzhou,No.3 Tianshan Road,New District,Changzhou,Jiangsu
  • Country/Region : China
  • Zip : 213022

Precision Digital LCR Meter TH2819A

Precision Digital LCR Meter TH2819A
Product Detailed
1.Precision LCR meter with frequency of 200kHz 2.Basic accuracy: 0.05% 3.6-digit display resolution 4.CE certification

Introduction

TH2819A is an updated product of TH2819 LCR meter with the features of TH2819, including easy operation, accurate and stable reading. It has smaller size than TH2819, nice appearance, and low cost.

With test frequency from 20Hz to 200kHz, frequency resolution of 10mHz, wide test signal level range from 5mV to 2V, measurement speed up to 32ms/time, TH2819A can be used to inspect electronic components, not only for measurement parameters TH2819 has, but DCR measurement. The meter has 1.5V/2V internal bias voltage, optional ±10V (±100mA) and 1A internal DC bias source and external inductance bias sources to inspect inductive components.

With high speed, wide test range, and 6-digit resolution, TH2819A can be used in quality control on production line, incoming inspection and lab measurement.

Measurement function

Measurement parameters

|Z|, |Y|, C, L, X, B, R, G, D, Q, θ ,DCR

Basic accuracy

0.1%

Equivalents circuit

Serial, Parallel

Math function

Absolute value deviation, percentage deviation

Range mode

Auto, Hold, Manual

Trigger mode

Internal, Manual, External

Measurement time (≥1kHz)

Fast: 32ms, Medium: 90ms, Slow: 650ms

Average time

1—255

Delay time

0—60s, with the step of 1ms

Correction

Open, Short, Load

Measurement terminal

5-terminal

Display mode

Direct, Δ, Δ%, V/I (voltage/current monitor)

Display

320×240 dot matrix graphic LCD display with 6-digit resolution

Test signal

Test signal frequency

20 Hz-200 kHz

Frequency min. resolution

10mHz

Output impedance

30 Ω, 100 Ω

Test signal level

Normal:       5 mV-2 V       Accuracy: 10%

Constant level: 10 mV-1 V      Accuracy: 5%

Level min. resolution

1mV

DC bias source

Internal

0V, 1.5V, 2V, accuracy: 1%

Optional

TH1902A 0-10V DC bias voltage, 0-100mA DC bias current

TH1902B 0-1A DC bias current

Measurement display range

|Z|, R, X

0.00001 Ω — 99.9999 MΩ

DCR

0.001 Ω — 99.9999 MΩ

|Y|, G, B

0.00001µS — 99.9999 S

C

0.00001 pF — 9.9999 F

L

0.00001 µH — 9999.99 H

D

0.00001 — 9.9999

Q

0.00001 — 9999.9

θ (DEG)

-179.999º — 179.999 º

θ (RAD)

-3.14159 — 3.14159

Δ%

-999.999% — 999.999%

Others

Comparator

10-bin sorting, bin counter

Storage

20 sets of LCRZ measurement settings saved

Interface

RS232C, HANDLER, GPIB (optional), USB HOST (optional)

Precision Digital LCR Meter TH2819A



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.